WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit, Low Pressure Propane Fire Pit Replacement Part

With 3/8" Flare Inlet & Outlet

WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit, Low Pressure Propane Fire Pit Replacement Part thumbnail-0
WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit, Low Pressure Propane Fire Pit Replacement Part thumbnail-1
WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit, Low Pressure Propane Fire Pit Replacement Part thumbnail-2
WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit, Low Pressure Propane Fire Pit Replacement Part thumbnail-3
WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit, Low Pressure Propane Fire Pit Replacement Part thumbnail-4

+ 5 more
& video

WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit, Low Pressure Propane Fire Pit Replacement Part | With 3/8" Flare Inlet & Outlet

$3998USD

Product details

  • 🔶Material: The fire pit gas control valve kit are made of high quality brass material with heavy-duty construction for durable use..
  • 🔶Application: Suitable for Low Pressure Repair Control System for Grill, Fire Pit, Fireplace & Heater.
  • 🔶Size: Thermocouple Length: 600mm/23.62inch; Head Tip: M8; Knob Diameter 44mm; "D" Insert for Valve: 6.0-6.1mm.
  • 🔶Thermocouple plays the role of a sensor, it senses the flame, will transmit a signal to the solenoid valve in the control valve, the solenoid valve receives the signal before opening the gas, in order to successfully ignite and keep the flame does not go out. So in the installation, the control valve and thermocouple should be well connected, so the control valve will receive the signal transmitted by the thermocouple, it will pass gas and ignite..
  • 🔶 2. The thermocouple and ignition needle in the installation of the distance should be closer, so the thermocouple can sense the flame and the solenoid valve receive the induction, pass gas and ignite..
$3998USD

Select location for accurate pricing, availability, and delivery estimates

Order today for delivery Sep 30 - Oct 1

Or by September 26 - 27 with expedited shipping

Delivery by: Snapklik.com FedEx Express logo

Ships from: Snapklik.com

Warehouse location: New York

In Stock

Product details

  • 🔶Material: The fire pit gas control valve kit are made of high quality brass material with heavy-duty construction for durable use..
  • 🔶Application: Suitable for Low Pressure Repair Control System for Grill, Fire Pit, Fireplace & Heater.
  • 🔶Size: Thermocouple Length: 600mm/23.62inch; Head Tip: M8; Knob Diameter 44mm; "D" Insert for Valve: 6.0-6.1mm.
  • 🔶Thermocouple plays the role of a sensor, it senses the flame, will transmit a signal to the solenoid valve in the control valve, the solenoid valve receives the signal before opening the gas, in order to successfully ignite and keep the flame does not go out. So in the installation, the control valve and thermocouple should be well connected, so the control valve will receive the signal transmitted by the thermocouple, it will pass gas and ignite..
  • 🔶 2. The thermocouple and ignition needle in the installation of the distance should be closer, so the thermocouple can sense the flame and the solenoid valve receive the induction, pass gas and ignite..
About this item

Operation Instructions 1). Fix the valve on a plate or board of your grill or fire pit by the head screw and flange. 2). Connect your inlet and outlet hose on inlet and outlet side. (faston it tightly enough in case of gas leakage) 3). Faston the thermocouple nut M*8 on the valve end tightly 4). Connect thermocouple and end thread well 5). Open gas by correct size knob and push your valve around 5-10s till the thermocouple head is heated enough. 6). Release your hand and it work properly If when you release hand, gas valve shut off again, Please check a. If your thermocouple is always be heated on flame b.

WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit, Low Pressure Propane Fire Pit Replacement Part detail 1
WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit, Low Pressure Propane Fire Pit Replacement Part detail 2

If the thermocouple end is well connect with valve c. If the inlet and outlet side well connect with hose you have Possible problems occurs during your use: 1) Valve after turn can not stick during using Reason: a. The thermocouple head is not heated in right place, please adjust thermocouple tip position. b. The connection between thermocouple end and valve is not connected tight enough or too tight, please adjust the screw again c. Need to push valve first then turn the spindle and hold for few seconds, it cannot stick immediately may need 5.

Product Information
SKID 02OC4PK7VF8O5
UPC 778299080125
Have an idea to help us improve?
Conditions of UsePrivacy Notice2019 - 2024 © Snapklik, Inc. or its affiliates